Liquid Treatment Systems' Locations (from NFPA 820 Table 5.2.72-RA-C GX-3R 4-Gas Confined Space Monitor, LEL / O2 / Combo H2S / CO with Li-Ion Battery Pack with 100-240 VAC Charger by RKI Instruments The unit is equipped with audible/visual alarms and also provides configurable relays for remote alarms. One input channel can be used to monitor the ventilation system. The sensors may be directly attached to the controller with a sampling pump unit to draw the gases from the detection points or mounted remotely at each detection point. It has up to 4 channels to allow a combination of gas detection and ventilation monitoring signals. ZoneProtector is an integrated gas detection unit that meets NFPA 820 requirements. Controller to monitor gas concentration and VentilationĬost-Effective Solution from R.C.Oxygen and H2S detectors should be set per OSHA requirements Methane gas detectors shall be set to alarm at 10 percent of the lower explosive limit (LEL) in accordance with the manufacturer’s calibration instructions and shall be connected to alarm signaling systems.What is required to have a gas detection system meet the requirement? Sludge Storage Wet Wells, Pits, Holding Tanks Area Solid Treatment Systems’ Locations (from NFPA 820 Table 6.2.2 ): Location LEL (CH4 Flammable gases and floating flammable liquids

NFPA 820 requires that all the ventilation of the hazardous location needs to be monitored.Ĭollection Systems’ Locations (from NFPA 820 Table 4.2.2 ): Location Refer to NEC Article 500 and NFPA 496 for more information. Proper ventilation of an area may reduce classification to Division 2 or non-classified. Most semi-enclosed and enclosed process areas in wastewater treatment facilities are classified as Class I, Division 1 or Division 2, Group D. Alarm Signaling for combustible gas detectors and ventilation are mandated by NFPA 820. Oxygen and Hydrogen Sulfide detection points are usually placed in the breathing zone for personnel protection. Methane Gas detection points are placed near the roof of a structure. Hydrogen Sulfide (H2S) and Oxygen (O2) monitoring are also frequently used.

Combustible Gas Detection, primarily for Methane (CH4), is required in many areas. The requirements shall be used by owners in a risk assessment to identify the areas of a treatment plant that are vulnerable to fire or other loss. The requirements shall apply to new installations, additions, or modifications made to existing facilities. NFPA 820, Standard for Fire Protection in Wastewater Treatment and Collection Facilities, establishes minimum requirements for protection against fire and explosion hazards in wastewater treatment plants. Gas Detection and Alarm Requirement from NFPA 820

NFPA 820 details requirements for protection at wastewater treatment facilities and collection facilities. Gas Detection of Tank Farms and Liquefied Gases.Gas Detection in Wastewater Treatment Plant.Detection in Wastewater Treatment & Collection Facilities.Gas Detection in the Food and Beverage Business.ZoneProtector Multi-point Monitoring (Meets NFPA 820).Calibration Gases, Kits and Accessories.64-Channel ViewSmart 6400 Alarm Controller.32-Channel WaveLink Receiver Wireless Alarm Controller.
4 GAS MONITOR IN BREATHING ZONE PLUS